FST-AC22V&440V-300KW Resistive AC Load Bank

Why load bank testing is important?

FORESIGHT series AC/DC load banks are for many power supplies load bank testing, to ensure that the standby power supply system say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc which especially located in harsh, dusty or corrosive environment working in good condition, when you need them most, if switched to be loaded when the main power supply in maintenance procedure or stop abnormally.

The AC/DC load bank loading test preventative maintenance of such power supply systems could free you from power supply failure, to ensure constant uptime for your power systems and make you prepared for anything. Downtime could also be reduced by regular maintenance and thorough inspections which are the key to power supply systems maintenance.

 

Load bank testing could help highlight a large range of faults on the power supply systems it test. The first goal achieved when testing with FORESIGHT AC/DC load bank is to ensure your power supply system is reliable or not by validating the power systems’ outputs to its technical specifications. The underlying question that FORESIGHT series AC/DC load bank could answer you is–“how is my power supply systems constant uptime(technical performance) ?” The load bank also tests that the power supply system is not faulty, no faults in construction and components reliable, that the aging of the power supply system is in line with expectations and that there are no pending breakdowns or early signs of wear and tear.

 

FORESIGHT offers you whole AC/DC load bank testing solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC/DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.

Description

Technical Specifications
   
Model FST-AC220V&440V-300KW-R Resistive AC Load Bank
Load Element Alloy resistors
Load Voltage AC220V 3phase 3wire, 50/60Hz

AC440V 3phase 3wire, 50/60Hz

Load Power 300KW for AC220V 3phase 3wire, 50/60Hz

300KW for AC440V 3phase 3wire, 50/60Hz

Load Steps

@AC440V 3P3W

Resistive Load Steps (three phase controlled):

10KW, 15KW*2, 30KW*2, 50KW*4

(10-300KW adjustable)

Load Steps

@AC220V 3P3W

Resistive Load Steps (three phase controlled):

10KW, 15KW*2, 30KW*2, 50KW*4

(10-300KW adjustable)

Power Factor PF=1.0
Load Accuracy ±5%
Digital Meter Voltage, Current, Power, Frequency, Power Factor and etc.
Control Power AC220V 3phase 3wire 50/60Hz

(Load bank fans & control power supply)

Control Mode 1.     Manual control by push button

2.     Remote control by PC software(optional)

Wire Connections Copper bus bar for wire connections
The Contactor  GHINT Contactor
Insulation Class F
Fan Noise 90dB
Cooling Mode Force-air cooling
Work Mode Continuous work
Protections Overheating/buzzer alarm, overheating/over voltage protection, emergency stop button
Ambient Temperature -10℃~+50℃
Dimension 1100*1370*1166mm(W*D*H)
Weight 350KG
Mobility 6 wheels
Humidity ≤95%
Altitude ≤2500 meters