FST-380V/400V 1000KW Resistive AC Load Bank
Why load bank testing is important?
FST series AC/DC load banks are for many power supplies load bank testing, to ensure that the standby power supply system say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc which especially located in harsh, dusty or corrosive environment working in good condition, when you need them most, if switched to be loaded when the main power supply in maintenance procedure or stop abnormally.
Load bank testing could help highlight a large range of faults on the power supply systems it test. The first goal achieved when testing with FST AC/DC load bank is to ensure your power supply system is reliable or not by validating the power systems’ outputs to its technical specifications. The underlying question that FST series AC/DC load bank could answer you is–“how is my power supply systems constant uptime(technical performance) ?” The load bank also tests that the power supply system is not faulty, no faults in construction and components reliable, that the aging of the power supply system is in line with expectations and that there are no pending breakdowns or early signs of wear and tear.
FST offers you whole AC/DC load bank testing solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated
Description
Technical Specifications | |
Model | FST-AC400V-1000KW-R Resistive AC Load Bank |
Load Element | Stainless steel resistors |
Load Voltage | AC400V 3Phase 4Wire, 50/60Hz |
Load Power | 1000KW for AC400V 3Phase 4Wire |
Rated Load Steps @AC415V | 5KW*2, 20KW*2, 50KW, 100KW*9
(5KW-1000KW adjustable) |
Power Factor | PF=1 |
Load Accuracy | ±5% |
Digital Meter | Voltage, Current, Power, Frequency and etc. |
Power Supply | AC400V 3phase 4wire 60Hz
(Load bank fans & control power supply) |
Control Modes | 1. Manual control by push button
2. PC software remote control 3. Hand held controller |
Wire Connections | Copper bus bar for wire connections |
Insulation Class | F |
IP Level | IP54 |
Fan Noise | 90dB |
Cooling Mode | Force-air VERTICAL cooling |
Work Mode | Continuous work |
Protections | Overheating/buzzer alarm, overheating/over voltage protection, emergency stop button |
Ambient Temperature | -10℃~+50℃ |
Dimension | 1600*1850*1800mm(W*D*H)(final dimension to be designed) |
Weight | Around 1.4T |
Mobility | Stationary & moved by forklift pocket |
Humidity | ≤95% |
Altitude | ≤2500 meters |
Reviews
There are no reviews yet.