FST-AC400V-100KW Resistive AC Load Bank
FORESIGHT series load banks protections
Standard protections:
- Emergency pause operation: one-key stop loading
- Over temperature alarm/protection: alarm & remove load
- Fan interlock protection: loading available after fan activated
- Over voltage protection: alarm & remove load
Optional protections
- Blower thermal overload protection: alarm & remove load
- Short circuit protection by fuse(over current protection)
- Phase sequence protection(for fans with 3phase voltage)
Or other functions as requested
FORESIGHT series load bank control modes
Two control modes available for FORESIGHT series AC/DC load banks: The local panel control mode and the PC software remote control mode.
Local panel control mode available as below listed:
- By contactor
Description
Technical Specifications | |
Model | FST-AC400V-100KW-R Resistive AC Load Bank |
Load Element | Stainless steel resistors |
Load Voltage | AC400V 3phase 4wire, 50Hz |
Load Power | 100KW for AC400V 3 Phase 4 Wire, 50Hz |
Load Steps | 1, 2, 2, 5, 10, 20, 20, 40(1KW-100KW adjustable) |
Power Factor | PF=1 |
Load Accuracy | ±5% |
Digital Meter | Voltage, Current, Power, Frequency and etc. |
Power Supply | 220V 50Hz, single phase |
Control Mode | 1. Manual control by push button
2. PC software by Remote control ( Optional) |
Wire Connections | Copper bus bar for wire connections |
Insulation Class | F |
Protection Level | IP20(indoor use) |
Fan Noise | 75dB |
Cooling Mode | Force-air cooling |
Work Mode | Continuous work |
Protections | Overheating/buzzer alarm, overheating/over voltage protection, emergency stop button |
Ambient Temperature | -10℃~+50℃ |
Dimension | 600*850*1300mm |
Weight | Around 180KG |
Mobility | Four wheels, lifting rings in chassis top |
Humidity | ≤95% |
Altitude | ≤2500 meters |