Data center & server room cooling system test Data center air flow, hot/cold aisle environment inspection Validating the tire level of data center Validating the reliability of data center power supply & distribution system Testing the main network before connecting user devices (servers, switches, etc.)
Tel:(+86) 029-85426859      Tel:(+86) 029-85426859

Description

Specification

Packing list

Datasheet download

The FST rack mounted AC & DC load banks are designed especially for internet data center (IDC) test and commissioning. Load bank integrated system test (IST) could precisely simulate the data center’s electricity consumption, heat dissipation, air flow, hot & cold aisle testing, thus to ensure the effective operation of power supply & distribution system (generator, UPS, EPS included), air conditioning system, lightning protection and earthing system, monitoring system, data center integrated environments, cabinet IT environment, providing independent verification of integrated system testing. Successful IST(integrated system test) should have installation of server load banks in data center 


and server room etc, FST provides resistive, reactive and capacitive load banks in low or medium voltage to cover the entire scope of your commission and testing requirements.

Applications:

Ø  Data center & server room cooling system test

Ø  Data center air flow, hot/cold aisle environment inspection

Ø  Validating the tire level of data center

Ø  Validating the reliability of data center power supply & distribution system

Ø  Testing the main network before connecting user devices (servers, switches, etc.)


Technical Specifications

Model

FST-AC220V-6KW-R Resistive AC Load Bank

Load Element

Stainless steel resistor

Load Voltage

AC220V single phase, 50/60Hz

Rated Power

6KW@AC220V

Load Steps

3 independent load channels: AC1, AC2, AC3

AC1 Load Channel (Fan power supply also): 2*1KW

AC2 Load Channel: 2*1KW

AC3 Load Channel: 2*1KW

Total 6 load steps: 1KW*6

Power Factor

PF=1

Load Accuracy

±5%

Power Supply

Fan activated by AC1 cable: 220V 1phase 50Hz from test source

Control Mode

Manual control by mini circuit breaker

Insulation Class

F

Protection Level

IP20(indoor use

Fan Noise

75dB

Cooling Mode

Fan force-air cooling, powered from the test source.

Cool air intake at front, hot air exhaust at rear.

Fan activated by AC1 cable: 220V 1phase 50Hz from test source

Work Mode

Continuous work

Ambient Temperature

-10℃+50℃

Load Input Cables

Three C19-C20 cables(Or other as per requested)

Dimension

4U 19 inch rack, depth 600mm

Weight

19KG

Mobility

Two front handles and one rear handle

Humidity

≤95%

Altitude

≤2500 meters

NOTE: Each load bank includes the standard items:

1.    One Load Bank Main Unit.

2.    Three C19-C20 cables

/manage/kindeditor/attached/file/20200701/20200701130906_98074.pdf

Online Inquiry

 
验证码,看不清楚?请点击刷新验证码  

Related Products


Copyright©2012-2015 All Right Reserved. Foresight Electronics Co, Ltd.