Resistive DC Load Bank
Inductive & Resistive AC Load Bank
Resistive AC Load Bank

FST-IAC415V-40A-R Resistive AC L...

Preventative maintenance products solutions for your UPS systems, generators and many more to ensure constant uptime for your power systems and make you prepared for anything。
Tel:(+86) 029-85426859      Tel:(+86) 029-85426859

Description

Specification

Packing list

Datasheet download


It is really critical to ensure that your standby power supply system say UPS(uninterrupted power supply), battery bank, generator, transformers, inverter etc which especially located in harsh, dusty or corrosive environment working in good condition, when you need them most, if switched to be loaded when the main power supply in maintenance procedure or stop abnormally.


Such power supply systems could fail without proper preventative maintenance. FST provides a whole range of custom preventative maintenance products solutions for your UPS systems, generators and many more to ensure constant uptime for your power systems and make you prepared for anything. Downtime could also be reduced by regular maintenance and thorough inspections which are the key to power supply systems maintenance.


FST AC load banks could help highlight a large range of faults on the power supply systems it test. The first goal achieved when testing with FST AC load bank is to ensure your power supply system is reliable or not by validating the power systems’ outputs to its technical specifications. The underlying question that FST series AC load bank could answer you is--“how is my power supply systems constant uptime(technical performance) ?” The load bank also tests that the power supply system is not faulty, no faults in construction and components reliable, that the aging of the power supply system is in line with expectations and that there are no pending breakdowns or early signs of wear and tear.


FST series AC load bank testing offers you whole solutions of predictive failure analysis for UPS(uninterrupted power supply), generator, transformers, PV system, inverter etc, to validate the condition and output of such power systems comprehensively. Integrated AC & DC load bank could be made in one unit or separately with different load voltages as per your need for different applications.


About FST load banks resistor

Highly reliable and durable new alloy resistor is used for the FST’s AC & DC load bank. It is thermal shrinkable and seal installed in the stainless steel pipe, whose surface with insulated heat sink. The resistor is moisture-proof, anti-corrosion, good heat dissipation, high insulation resistance, safe and reliable.

FST load bank control modes(remote control is optional)

Two control modes available for FST AC load banks: The local panel control mode and the remote control mode by PLC through PC software. Local control mode will be locked once load bank is switched to remote control mode. By applying the PLC, we could make load bank an intelligent test system, load power curve could be preset through PC software and all electrical parameters of EUT(equipment under test) including current, voltage, apparent power, active power, reactive power, power factor, frequency and warning info could be achieved automatically by the PC software and displayed by load bank digital meter. Up to 15 load banks at most could be parallel controlled by PC software which generating the test tables, curves and standard test report.



Technical Specifications

Model

FST-IAC415V-40A-R Resistive AC Load Bank

Load Element

Alloy resistors

Load Voltage

AC415V 3 phase 4 Wire, 50Hz, or lower voltage

(Load Voltage DO NOT exceed AC415V)

Load Step(ohm)

Phase A: 0.1, 0.2, 0.2, 0.5, 1, 1, 2, 2, 5, 10, 20, 40, 60, 100(Ω)

Phase B: 0.1, 0.2, 0.2, 0.5, 1, 1, 2, 2, 5, 10, 20, 40, 60, 100(Ω)

Phase C: 0.1, 0.2, 0.2, 0.5, 1, 1, 2, 2, 5, 10, 20, 40, 60, 100(Ω)

(0.1 to 242 ohm adjustable per phase)

Power Factor

PF=1

Load Accuracy

±5%

Digital Meter

Voltage, Current, Power, Frequency and etc.

Power Supply

240V 50Hz, single phase

Control Mode

Manual local panel control by push button

Insulation Class

F

Protection Level

IP20(indoor use)

Fan Noise

75dB

Cooling Mode

Vertical force-air cooling

Work Mode

Continuous work

Protections

Overheating/buzzer alarm, overheating/over current protection, emergency stop button

Ambient Temperature

-10℃+50℃

Dimension

600*850*1260mm

Weight

180KG

Mobility

Four wheels, lifting rings in chassis top

Humidity

≤95%

Altitude

≤2500 meters


/manage/kindeditor/attached/file/20200622/20200622100942_88387.pdf

Online Inquiry

 
验证码,看不清楚?请点击刷新验证码  

Related Products