FORESIGHT series AC/DC load banks
are for many power supplies load bank testing, to ensure that the standby power
supply system say UPS(uninterrupted power supply), battery bank, generator,
transformers, inverter etc which especially located in harsh, dusty or
corrosive environment working in good condition, when you need them most, if
switched to be loaded when the main power supply in maintenance procedure or
stop abnormally.
The AC/DC load bank loading test
preventative maintenance of such power supply systems could free you from power
supply failure, to ensure constant uptime for your power systems and make you
prepared for anything. Downtime could also be reduced by regular maintenance
and thorough inspections which are the key to power supply systems maintenance.
Load bank testing could help
highlight a large range of faults on the power supply systems it test. The
first goal achieved when testing with FORESIGHT AC/DC load bank is to ensure
your power supply system is reliable or not by validating the power systems’
outputs to its technical specifications. The underlying question that FORESIGHT
series AC/DC load bank could answer you is--“how is my power supply systems
constant uptime(technical performance) ?” The load bank also tests that the
power supply system is not faulty, no faults in construction and components
reliable, that the aging of the power supply system is in line with
expectations and that there are no pending breakdowns or early signs of wear and
tear.
FORESIGHT offers you whole AC/DC
load bank testing solutions of predictive failure analysis for
UPS(uninterrupted power supply), generator, transformers, PV system, inverter
etc, to validate the condition and output of such power systems comprehensively.
Integrated AC/DC load bank could be made in one unit or separately with
different load voltages as per your need for different applications.
FORESIGHT
AC/DC load banks applications
Ø Battery bank system
Ø Energy storage system
Ø Energy meter loop load test
Ø Datacenter rack heat
simulating
Ø PV system Inverter
anti-islanding test
Ø Voltage regulator,
rectifier aging load test
Ø Genset, UPS load bank
commission testing
Ø AC/DC power supply,
power source commission acceptance test
|
FORESIGHT
series load banks loading elements (load bank types)
Alloy resistors, inductors
& capacitors loading elements are combined used in FORESIGHT series AC/DC
load bank as per clients’ need in different applications:
Ø Pure resistive AC load
bank
Ø Pure resistive DC load
bank
Ø RCD non-linear AC load
bank
Ø Resistive &
inductive combined AC load bank
Ø Resistive, inductive
& capacitive combined AC load bank
|
FORESIGHT series load banks
protections
Standard protections:
Ø Emergency pause operation: one-key stop loading
Ø Over temperature alarm/protection: alarm & remove load
Ø Fan interlock protection: loading available after fan activated
Ø Over voltage protection: alarm & remove load
|
Optional protections
Ø Blower thermal overload protection: alarm & remove load
Ø Short circuit protection by fuse(over current protection)
Ø Phase sequence protection(for fans with 3phase voltage)
Ø Or other functions as requested
|
FORESIGHT series load bank
control modes
Two control modes available for
FORESIGHT series AC/DC load banks: The
local panel control mode and the PC software remote control mode.
Local
panel control mode available as below listed:
Ø By contactor
Ø By circuit breaker
Ø Or other switches as
requested
|
PC software remote control(optional)
FORESIGHT
series AC/DC load bank remote control
communication protocol would be provided for clients’ integrating the load
bank into the ATE system
|
Technical Specifications
|
Model
|
FST-AC415V-100KW-R Resistive AC Load Bank
|
Load Element
|
Stainless steel resistors
|
Load Voltage
|
AC415V 3phase 4wire, 50/60Hz
AC240V 1phase 2wire, 50/60Hz
|
Load Power
|
100KW for AC415V 3Phase 4Wire, 50/60Hz
100KW for AC240V 1Phase 2Wire, 50/60Hz
|
Load Steps
|
1, 2, 2, 5, 10, 20, 20, 40(1KW-100KW adjustable)
|
Power Factor
|
PF=1
|
Load Accuracy
|
±5%
|
Digital Meter
|
Voltage, Current, Power, Frequency and
etc.
|
Power Supply
|
240V 50Hz, single phase
|
Control Mode
|
Manual control by push button
|
Wire Connections
|
Copper bus bar for wire connections
|
Insulation Class
|
F
|
Protection Level
|
IP20(indoor use)
|
Fan Noise
|
75dB
|
Cooling Mode
|
Force-air cooling
|
Work Mode
|
Continuous work
|
Protections
|
Overheating/buzzer alarm, overheating/over
voltage protection, emergency stop button
|
Ambient Temperature
|
-10℃~+50℃
|
Dimension
|
600*850*1300mm
|
Weight
|
Around 180KG
|
Mobility
|
Four wheels, lifting rings in chassis top
|
Humidity
|
≤95%
|
Altitude
|
≤2500 meters
|
/manage/kindeditor/attached/file/20200628/20200628211519_35834.pdf